0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TEQ 200-4812WIR

TEQ 200-4812WIR

  • 厂商:

    TRACOPOWER

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
TEQ 200-4812WIR 数据手册
DC/DC Railway Converter • High power block with excellent thermal convection • Operating temperature -40°C to +70°C without derating • • • Increased shock & vibration resistance • • • • • Excellent efficiency up to 90% TEQ 200WIR Series, 200 Watt Ultra wide 4:1 input voltage range EN 50155 approval for railway applications Input filter meet EN 55032, class A I/O insulation 1591 VAC Under voltage lock-out circuit Soft start UL 508 UL 62368-1 IEC 62368-1 The TEQ 200WIR Series is a family of isolated high performance DC/DC converter modules with ultra-wide 4:1 input voltage ranges which come in a rugged, sealed metal case. These converters are suitable for a wide range of applications, but the product is designed particularly also for industrial applications where often no PCB mounting is possible but the module has to be mounted on a chassis. A very high efficiency and the overall heatsink construction allows an operating temperature up to +70°C with natural convection cooling without power derating and up to +90°C with power derating. Further features include output voltage trimming, Remote On/Off and under voltage lockout. The very wide input voltage range and reverse input voltage protection make these converters also an interesting solution for battery operated systems. Models Order Code Input Voltage Output Voltage Output Current Efficiency Range nom. (adjustable) max. typ. 12 VDC (9.6 - 13.2 VDC) 18'000 mA 89 % 24 VDC (19.2 - 26.4 VDC) 9'000 mA 89 % 28 VDC (22.4 - 30.8 VDC) 7'500 mA 90 % TEQ 200-4812WIR TEQ 200-4815WIR TEQ 200-4816WIR 19 - 75 VDC (48 VDC nom.) TEQ 200-4818WIR 48 VDC (38.4 - 52.8 VDC) 4'500 mA 89 % TEQ 200-7212WIR 12 VDC (9.6 - 13.2 VDC) 20'000 mA 88 % 24 VDC (19.2 - 26.4 VDC) 10'000 mA 88 % 28 VDC (22.4 - 30.8 VDC) 8'500 mA 89 % 48 VDC (38.4 - 52.8 VDC) 5'000 mA 88 % TEQ 200-7215WIR TEQ 200-7216WIR TEQ 200-7218WIR 43 - 160 VDC (110 VDC nom.) Options TEQ-MK1 - Optional DIN-Rail Mounting Kit: www.tracopower.com/products/teq-mk1.pdf www.tracopower.com November 30, 2022 Page 1 / 4 TEQ 200WIR Series, 200 Watt Input Specifications Input Current - At no load 48 Vin models: 110 Vin models: 48 Vin models: 110 Vin models: 48 Vin models: 110 Vin models: Surge Voltage Under Voltage Lockout Recommended Input Fuse Input Filter 23 mA typ. 13 mA typ. 100 VDC max. (1 s max.) 185 VDC max. (1 s max.) 15.5 VDC min. / 16.5 VDC typ. / 18 VDC max. 33 VDC min. / 35.5 VDC typ. / 38 VDC max. (The need of an external fuse has to be assessed in the final application.) Internal Common Mode Choke + Pi-Type Output Specifications Output Voltage Adjustment Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise (20 MHz Bandwidth) Capacitive Load 12 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: 12 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: 12 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: 12 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: - 48 Vin input - 110 Vin input Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response - Response Time –20% to +10% (By trim potentiometer) Output power must not exceed rated power! ±1% max. 0.1% max. 0.1% max. 100 mVp-p typ. 200 mVp-p typ. 200 mVp-p typ. 300 mVp-p typ. 125 mVp-p max. 250 mVp-p max. 250 mVp-p max. 350 mVp-p max. 15'000 µF max. 3'700 µF max. 2'600 µF max. 930 µF max. 16'600 µF max. 4'100 µF max. 3'000 µF max. 1'000 µF max. Not required ±0.02 %/K max. 75 ms typ. Continuous, Automatic recovery 120 - 150% of Iout max. 115 - 130% of Vout nom. 200 µs typ. / 250 µs max. (25% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment - Industrial Control Equipment - Railway Applications - Certification Documents Pollution Degree Over Voltage Category EN 62368-1 IEC 62368-1 UL 62368-1 UL 508 EN 50155 www.tracopower.com/overview/teq200wir PD 2 OVC II All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4 TEQ 200WIR Series, 200 Watt EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions EMS Immunity - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge - Conducted RF Disturbances - PF Magnetic Field EN 50121-3-2 (EMC for Rolling Stock) EN 55011 class A (internal filter) EN 55032 class A (internal filter) EN 55011 class A (internal filter) EN 55032 class A (internal filter) EN 50155 (Railway Applications) EN 50121-3-2 (EMC for Rolling Stock) EN 55024 (IT Equipment) EN 61204-3 (Low Voltage Power Supplies) Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 20 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A EN 61000-4-6, 10 Vrms, perf. criteria A Continuous: EN 61000-4-8, 100 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating Over Temperature Protection Switch Off Cooling System Sense Function Remote Control - Protection Mode - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Working Voltage (rated) Isolation Test Voltage Isolation Resistance Reliability - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s - Input to Output, 500 VDC - Calculated MTBF Environment - Vibration - Mechanical Shock - Thermal Shock Housing Material Potting Material Housing Type Mounting Type Connection Type Weight 95% max. (non condensing) –40°C to +90°C –40°C to +105°C Depending on model - Operating Temperature - Storage Temperature - High Temperature See application note: www.tracopower.com/overview/teq200wir 105°C min. / 115°C typ. / 120°C max. (Automatic recovery) Natural convection (20 LFM) 10% max. of Vout nom. On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 8 mA max. -0.5 to 1.0 mA 2'000 m max. 225 - 275 kHz (PWM) 250 kHz typ. (PWM) Reinforced Insulation 182 VAC 2'250 VDC 1'600 VDC 1'600 VDC 1'000 MΩ min. 270'000 h (MIL-HDBK-217F at 55°C, ground benign) MIL-STD-810F EN 61373 MIL-STD-810F EN 61373 MIL-STD-810F EN 50155 Aluminum Silicone (UL 94 V-0 rated) Metal Case Chassis Mount Spring Clamps 800 g All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4 TEQ 200WIR Series, 200 Watt Thermal Impedance - Case to Ambient Environmental Compliance - REACH Declaration 1.45 K/W typ. www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf - RoHS Declaration Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) www.tracopower.com/info/en45545-declaration.pdf - Flammability (EN 45545-2) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/teq200wir Outline Dimensions 103.2 (4.06) 79.1 (3.114) 7 8 9 10 11 12 1 2 3 4 5 6 3.2 (0.13) TOP VIEW Terminal Pin Function Recommended Wire 1,2 –Vin 12 AWG 3 NC NC 4 Remote 14 - 18 AWG 5, 6 +Vin 12 AWG 7, 8 –Vout 12 AWG 9 –Sense* 14 - 18 AWG 10 +Sense* 14 - 18 AWG 11, 12 +Vout 12 AWG NC: No Connection Output voltage adjust Dimensions in mm, (inch) Tolerances: x.xx ±0.5 (±0.02) Terminal connection Output ON LED 74.2 (2.92) 76.2 (3.00) 88.9 (3.50) 87.6 (3.45) Screw 4–M3X0.5 © Copyright 2022 Traco Electronic AG * Sense line to be connected to the output either at the module or at the load under regard of polarity. • The current rating of the terminal block is 15 A/pole. • Using 2 poles in parallel if the peak output current can exceed 15 A. • Wire size shall be selected to withstand the peak output current (Iout max + Current limitation). Specifications can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4
TEQ 200-4812WIR 价格&库存

很抱歉,暂时无法提供与“TEQ 200-4812WIR”相匹配的价格&库存,您可以联系我们找货

免费人工找货